TITANIC
MEDICAL HYPERBARIC CHAMBER
3.0 - 6.0 ATA PRESSURE
12+2 SEATS

During treatment, the patient breathes high-purity oxygen directly from the BIBS mask (Built-In Breathing system). The oxygen is supplied from the medical facility’s oxygen tanks.

The BIBS regulator is designed to circulate oxygen effectively through the polyurethane hose while removing carbon dioxide. This feature ensures a safe and controlled therapy environment and always pure oxygen breathing.

System features

External Control Panel

Your command center for hyperbaric oxygen sessions

Navigate pressure adjustments, monitor vital information, maintain clear communication with your patient, and control every aspect of the chamber with confidence. Be prepared for any situation with manual overrides and an emergency stop button. Take control of patient well-being and elevate your hyperbaric therapy experience.

CONTROL SCREEN

Manage everything with the built-in mini-computer, from setting the pressure and session parameters to locking the chamber door. Monitor the session with clear visuals and data on chamber pressure, time, and other vital information.

EXTERNAL INTERCOM

Provides voice connection with the users and assistants inside. It’s always open for crystal clear communication with volume control.

MANUAL COMPRESSION KNOB

Take command with the manual pressure knobs, adjusting compression and decompression independently of the automatic system for greater control.

MANUAL DECOMPRESSION KNOB

Take command with the manual pressure knobs, adjusting compression and decompression independently of the automatic system for greater control.

EMERGENCY STOP BUTTON

Peace of mind control: Terminates session in the pressure room if needed, and quickly drops chamber pressure to a safe level.

POWER ON SWITCH

Start your session: The switch turns on the electrical equipment, activating the control panels for manual and/or automatic HBOT sessions.

EMERGENCY DECOMPRESSION VALVE

In case of emergency, the pressure chamber is relieved by rotating the manual spherical valve from inside or outside the chamber.

VIDEO CAMERA MONITORING

The hyperbaric chamber is equipped with multiple interior cameras to monitor the patients’ response to hyperbaric oxygen therapy. The cameras cover all angles and the video is broadcast live on the control panel.

Software control

The control consoles, located on the outside and inside the chamber, provide the controls and instrumentation for chamber operation. This includes the gas control systems and communications system. Chamber control is fully automated via the Automation System.

Advanced monitoring & safety systems

HPO TECH systems are equipped with advanced monitoring sensors to track, monitor and control essential parameters during the therapy session. These monitoring capabilities allow healthcare providers to closely observe the patient’s response, adjust treatment if necessary, and assess the overall progress of the therapy.

Automation system

The Automation System controls the chamber and runs sessions automatically. It consists of automation software, industrial PLC, sensors, valves, and PC.

The PLC is the core of the system, monitoring and controlling all connected devices (sensors, valves, etc.). The specific devices and functions controlled depend on customer configuration.

Tracking session progress and user data in real-time

Real-time session information is gathered from sensors and displayed to monitor session status.

The monitoring systems track essential parameters, including atmospheric pressure, oxygen concentration, temperature, humidity, patient vitals, and treatment duration. Real-time monitoring enhances patient safety and empowers the medical team to make informed decisions.

Session status management

  • Automatic session control for speed, pressure, and time
  • Entry of new treatment profiles
  • Chamber ventilation
  • I/O calibration and other functions
  • Logging, reviewing, and printing tools
  • Session and patient information access
  • Opening sessions for Automation Software
  • Valve control by dimmer
  • Lighting On/Off
  • UVC On/Off
  • Radiator On/Off
  • Real-time monitoring of temperature, humidity, pressure, and oxygen
  • Audio/visual warnings to the operator
  • Audible warning signal and safety button
  • Valve openings or maximum compression/decompression rate settings
  • Ear opening assistance
  • Session recording

Smart technology, user-friendly operation.

Combine comfort, safety, and user interaction for an exceptional hyperbaric experience.

Simple operation

All chamber components (hardware and software) are designed for ease of operation and require minimum maintenance.

Always in contact

Advanced monitoring and communication systems ensure continuous patient care. You can hear, see, and monitor the patient at all times during treatment.

Patient monitoring

Chamber penetrations and electrical connectors provide the capability to connect vital monitoring (such as EEG, ECG, TCOM and blood pressure).

Entertainment system

The chamber is equipped with large-screen TV, or tablets for the users, including other customizable additions.

LED Lights

You can create a serene atmosphere inside with adjustable LED RGB lights.

Ventilation

The automatic ventilation system ensures the air inside is always fresh.

Pneumatic controls

Chamber controls are completely pneumatic in nature, and require only a compressed gas source.

Power source

A discrete power source allows continued operation of chamber communications in the event of a power outage.